LCL Awards Logo
Find a centre near you Follow LCL Awards on Facebook Follow LCL Awards on LinkedIn
LEARNER ZONE CENTRE ZONE QUALIFICATIONS INCLUSIVITY CONTACT US ABOUT US NEWS
  • HOME
  • LEARNER ZONE
  • CENTRE ZONE
  • QUALIFICATIONS
  • INCLUSIVITY
  • CONTACT US
  • ABOUT US
  • NEWS
  • PHONE US
    EMAIL US
  • Home /
  • Qualifications /
  • Regulated Qualification in Fluorinated Greenhouse Gases on Refrigerant Systems (F-Gas Category I-IV)
Qualification Details

Regulated Qualification in Fluorinated Greenhouse Gases on Refrigerant Systems (F-Gas Category I-IV)

The following training and assessment packages are certificated by LCL Awards to industry led standards

Title Content type

Qualification Title

Regulated Qualification in Fluorinated Greenhouse Gases on Refrigerant Systems (F-Gas Category I-IV)

Sector Subject Area (SSA) & Industry Sector

Refrigeration & F-Gas Qualifications

LCL Awards Qualification Number

F-Gas CI, F-Gas C2, F-Gas C3, F-Gas C4

Qualification Regulator(s) number

603/1917/3 – Cat l

603/1918/5 – Cat ll

603/1919/7 – Cat lll

603/1920/3 – Cat lV

Qualification Level and Credit Value

Level 3 (Cat I & II), Level 2 (Cat III & IV)

Qualification Duration

Category l: 31 GLH: 31 TQT: Category ll: 31 GLH: 31 TQT: Category lll: 7 GLH: 7 TQT: Category lV: 14 GLH: 14 TQT:

Qualification Unit Titles

The Installation and Maintenance of Equipment and Appliances Containing Fluorinated Gases

Qualification Information

These regulated RQF qualifications are for learners that wish to work in the refrigeration, air conditioning and heat pump industries with fluorinated greenhouse gasses.

These qualifications are designed for learners to meet the requirements of Regulation (EU) 2015/2067.

  • LCL Awards Level 3 Award in F-Gas: Install, Service, Maintain, Recovery, Decommission and Leakage Checking of Systems (Category I)
  • LCL Awards Level 3 Award in F-Gas: Install, Service, Maintain, Recovery, Decommission and Leakage Checking of Refrigerant Systems with a Charge of less than 3kg (6kg if hermetically sealed) (Category II)
  • LCL Awards Level 2 Award in F-Gas: Recovery of Refrigerant Systems with a Charge of less than 3kg (6kg if hermetically sealed) (Category III)
  • LCL Awards Level 2 Award in F-Gas: Leakage Checking of Refrigerant Systems (Category IV)

 

In GB & NI, the EU F-Gas Regulation is implemented by the Fluorinated Greenhouse Gases Regulations 2015 (SI No. 310) & NI (SI No. 425).  LCL Awards is a named personnel certification and evaluation body as set out in Part 3, Article 8(1) and (NI Part 2, Article 6(1)) of these Regulations, which relate to the certification and evaluation bodies for the purposes of Article 4 of Commission Regulation (EU 2015/2067 (issue and contents of certificates).

Confirmation can be viewed on the Gov.Uk web site here

Design Standards

Learning Outcomes and Assessment Criteria

  • The learner will know the fundamental principles of thermodynamics.
  • The learner will know the environmental impact of refrigerants and corresponding environmental regulations.
  • The learner will be able to carry out checks before putting in operation, after a long period of non-use, after maintenance or repair intervention, or during operation.
  • The learner will be able to check for leakage.
  • The learner will be able to handle the system and refrigerant during installation, maintenance, servicing or recovery in an environmentally friendly manner in accordance with the regulations.
  • The learner will be able to put into operation and maintain reciprocating, screw and scroll compressors, single and two-stage.
  • The learner will be able to install, put into operation and maintain air cooled and water cooled condensers.
  • The learner will be able to install, put into operation and maintain air cooled and water cooled evaporators.
  • The learner will be able to install, put into operation and the servicing of Thermostatic Expansion Valves (TEV) and other components.
  • The learner will be able to build a leak-tight piping system in a refrigeration installation.

The learner will know the information on relevant technologies.

Prerequisites

Category I & II are Level 3 CPD qualifications designed for learners working within the Refrigeration and or related service sector. Learners wishing to undertake Category (I) or (ll) qualifications must hold a recognised qualification in Refrigeration, Heating & Ventilation or other related industry sector or have a minimum of 2 years auditable experience working within the Refrigeration or Heating & Ventilation sector.

All learners must have a good practical working knowledge of different soldering and brazing methods to undertake this type of work. 

Learners registered on and undertaking an apprenticeship or qualification which has a requirement for Category I or II F-Gas classification are exempt from the published pre-requisites above.

Category III & IV are Level 2 qualifications and have no pre-requisites, they may be undertaken by any learner after initial assessment by the approved centre.

The Installation and Maintenance of Equipment and Appliances Containing Fluorinated Gases

Examination and or Assessment method(s)

E-Examination and a Practical Assessment

Related Qualifications

  • LCL Awards Level 3 Award in Understanding the properties and use of flammable refrigerants in accordance with ACRIB specification (A2L, A2 and A3)
  • LCL Awards Level 3 Award in Oxy-Fuel brazing within the RACHP sector

Related Document(s)

  • Qualification Specification for LCL Awards L2 & 3 Fgas

Related links and support material

DEFRA ACRIB guidance on careers and training

Standard Qualification Fee

– excludes VAT where applicable
£62.15 Cat I, £62.15 Cat II, £53.70 Cat III and £53.70 Cat IV

Frequently asked questions about this course

FIND AN APPROVED CENTRE NEAR YOU

LCL Awards logo
Tel: 020 8839 2439
enquiries@LCLawards.co.uk
LEARNER ZONE CENTRE ZONE QUALIFICATIONS CONTACT US
LCL Awards, Unit 1, Belvue Business Centre, Belvue Road, Northolt, Middlesex, UB5 5QQ
LCL Awards is a trading name of Logic Certification Ltd. Registered in England. Company No: 4615993
Copyright © LCL Awards 2025. All rights reserved
Terms of Use Privacy Policy